BPBJV Mining Flameproof Medium-Voltage Converter
Other Series

BPBJV Mining Flameproof Medium-Voltage Converter

Wolong BPBJV Mining Flameproof Medium-Voltage Converter: 1250 - 1600 kW, 6 kV, 10 kV, Ex d [ib] I. Quote within 24 hours.
Download product catalogs →
  • Genuine Wolong NanyangOriginal factory nameplate, test report and documents
  • Certified for hazardous areasATEX, IECEx, CSA, EAC, CNEX and CCC certificates held by Wolong Nanyang
  • Model check in 24 hoursEngineers match power, voltage, Ex marking and mounting
  • Worldwide deliverySeaworthy export packing, CIF or with your forwarder

Product Description

The BPBJV mining flameproof medium-voltage converter combines 10 kV switchgear, a phase-shifting transformer (replacing a mobile substation) and a cascaded multilevel converter in one integrated, water-cooled unit. It drives the motor directly without an output filter.

Key Specifications

SeriesBPBJV
Input voltage6 kV, 10 kV
Input frequency50 Hz, 60 Hz
Output voltage0 - 3.3 kV
Output frequency0 - 50 Hz
Power range1250 / 1600 kW per unit, 2 × 1600 kW combined
Coolingwater cooling with separated inner and outer circuits
Explosion protectionEx d [ib] I

Applications

Conveyors, pumps and fans fed directly from the 6 / 10 kV mine supply.

Documents Supplied

For each order we can provide the technical data sheet, outline drawing, routine test report and, for explosion-proof equipment, a copy of the Ex certificate that matches the nameplate marking. Tell us in the inquiry which documents your project or your inspector requires, so they are prepared before shipment.

Related Products

Explosion Protection Explained

The marking Ex d [ib] I combines a flameproof enclosure ("d") for the power section with intrinsically safe ("ib") control and signal circuits. Group I equipment is designed for underground coal mines where methane (firedamp) and coal dust may be present.

Two Topologies

Multilevel (BPBJV): a built-in phase-shifting transformer takes 6 or 10 kV directly and feeds nine three-phase low-voltage power cells; three cells in series per phase give 27-pulse rectification and a 13-level output. No separate transformer is needed.

Three-level (BPJV): 6- or 12-pulse rectifier fed from the mine's own transformer (two 1903 V windings), 5-level line-to-line output with an output reactor. The combined version uses separate DC links, so if one converter trips the other keeps running.

Catalog Data

Input10 kV or 6 kV (-15 % / +10 %), 50 Hz; three-level version also 3.3 kV
Output0 - 3.3 kV, 0 - 50 Hz; 0 - 219 A (1250 kW) or 0 - 280 A (1600 kW)
Overload110 % continuous, 120 % for 30 min, 180 % for 2 s
ControlV/F or sensorless vector control, two-quadrant operation
CoolingWater cooling, external water pressure below 3 MPa, flow above 130 L/min
Operator interface10.2-inch colour screen, metal push-buttons and intrinsically safe wireless mouse (Uo 1.65 V, Io 1.47 A)
Explosion protectionEx d [ib] I Mb
ModelOutputSize L × W × H (mm)Weight (kg)
BPBJV-1250/10/3.31250 kW4580 × 1360 × 165015000
BPBJV-1600/10/3.31600 kW4580 × 1360 × 165015000
BPJV-1600/3.31600 kW2070 × 1140 × 13425500
BPJV-2×1600/3.32 × 1600 kW2990 × 1140 × 13806800

Model example: BPBJV-1250/10/3.3 = mining flameproof and intrinsically safe transformer-converter, voltage source, 1250 kW, 10 kV input, 3.3 kV output.

Common Questions

What power range does the BPBJV cover?

The BPBJV covers 2 - 3.3 kV.

Which voltages are available for the BPBJV?

Rated voltage: 6 kV, 10 kV. Other voltages can be checked on request.

Which explosion protection does the BPBJV have?

The marking is Ex d [ib] I. Tell us the zone, gas group and temperature class of your site and we confirm the right version.

How is the BPBJV cooled?

Cooling method: water cooling with separated inner and outer circuits.

How to Order

For a fast, accurate quotation please send: rated power (kW), voltage and frequency, motor rating and load type, supply voltage, hazardous-area requirements, quantity and destination port. For a replacement, a photo of the old motor nameplate is the quickest way to match it. Lead time (about 80 days), documents and shipping are explained on our Export Service page.

Frequently Asked Questions

Do your explosion-proof motors have ATEX and IECEx certificates?

Yes. Wolong Nanyang explosion-proof motors, both low-voltage and high-voltage, are available with ATEX and IECEx certificates for Europe and international projects, and GOST for the Russian market. Tell us which certificate you need when you ask for a quote.

Can this motor replace my existing motor?

Yes. For new projects we quote and select the model to your requirements. For a replacement, please send a nameplate photo or outline drawing of the old motor, and we will match the shaft height, mounting and installation dimensions.

Can you supply replacements for Schorch, Brook Crompton or Morley motors?

Yes. Schorch, Brook Crompton and Morley belong to the Wolong Electric Group, and we can supply Wolong motors built to replace them, matched to your mounting dimensions.

Can you ship to my country, and what is the lead time?

Yes. We ship worldwide on CIF terms, or you can use your own forwarder. The usual production time is about 3 months, depending on the model and quantity.

What information do you need for a quotation?

Rated power (kW), voltage and frequency, number of poles or speed, Ex marking or hazardous zone, mounting type (e.g. B3, B35, V1), quantity and destination port. A nameplate photo of the old motor helps if it is a replacement.

Get a Quote for BPBJV Mining Flameproof Medium-Voltage Converter

Send us your requirements. An engineer will reply with a model check and price within 24 hours.

We only use your details to reply to this inquiry.

TEL

+86 13609288011

Motor Price Inquiry

WhatsApp QR code

WhatsApp