How to clean insulated bearings?
In the application process of insulated bearings for large motors, cleaning and maintenance are the key to ensure the normal operation of the motor. How to clean insulated bearings? Is it the same as the cleaning method of ordinary bearings? The editor will share with you the cleaning method of insulated bearings:

Before assembling, the insulated bearings must be carefully cleaned, and the cleaning agent is generally gasoline or kerosene.
1. To clean the insulated bearings, they should be immersed in anti-rust grease. The thickness of the oil film can be achieved by controlling the temperature or viscosity of the anti-rust grease. The method of adhering a layer of anti-rust grease to its surface. When brushing, pay attention to evenly apply it on the surface of the insulated bearing, do not cause accumulation, and also pay attention to prevent leakage!
2. Before installing the bearing seat, it should also be thoroughly cleaned and inspected. Scrape the dirt from the inner cavity of the bearing seat with a scraper, wipe the dirt with a cloth dipped in gasoline or solvent, and check for cracks and sand holes to prevent oil leakage during operation.
The joint surface between the bearing cover and the bearing seat, and the joint surface between the bearing seat and the bearing oil retaining ring should be scraped and matched, and checked with a feeler gauge. The gap should not be greater than 0.03 mm.
The surface of the bottom plate where the bearing seat is placed should also be cleaned. There should be no bruises, rust and burrs. The screws and seat plate threads that fasten the bearing seat should be carefully checked, and the screws should be screwed in to check whether they are too tight or bald.
The insulating bearing and the bearing seat should be cleaned at the same time and installed correctly to achieve the purpose of cleaning the insulating bearing!
The method of testing insulation of insulating bearings
The outer surface of the outer ring or inner ring of the insulating bearing has a layer of aluminum oxide coating about 100μm thick, which can withstand a voltage of at least 1000V. For some application equipment that needs to withstand higher voltages, bearings with alumina coating thickness exceeding 300μm can also be provided. The insulating coating of the insulating bearing can effectively prevent the passage of alternating current and direct current, avoid the electro-corrosion of the bearing by the induced current, prevent the damage of the current to the grease, rolling elements and raceways, and increase the service life of the bearing. The minimum resistance of the insulating bearing coating is 50 megohms. Experiments show that the insulating coating will be electrically broken down only when it is above 3000V.
Insulated bearings are mainly used in motors, generators and other electrical appliances and equipment with shaft currents. The main structural forms are: deep groove ball bearings, cylindrical roller bearings, tapered roller bearings and four-point contact ball bearings. Insulation resistance is a key technical indicator of insulating bearings. It must be tested during factory inspection to ensure that the insulation resistance value under DC 1000 V is not less than 100 MΩ. When testing the insulation resistance, it is necessary to simulate the installation conditions of the bearing and accurately measure the insulation resistance value to ensure that the insulation performance of the bearing meets the use requirements. If the conductive medium cannot ensure good contact with the insulating coating, it is possible to miss weak points with low insulation resistance, resulting in the insulation resistance weak points being broken down during the use of the bearing and causing electrical corrosion failure.
It is understood that there are two main insulation resistance test methods commonly used in China:
1) After the bearing is coated with a metal strip conductive medium (such as copper strip, aluminum foil, etc.), the measurement is performed. However, since the metal conductive medium cannot be guaranteed to be in good contact with the insulating coating during the measurement process, the test results are not accurate enough;
2) The insulating bearing is pressed into the bearing seat for measurement. Since the pressing will cause damage to the bearing appearance, it is not suitable for the bearing manufacturer to conduct a full inspection. In order to ensure that the insulating coating of the bearing is in good contact with the conductive medium during the measurement process and does not affect the appearance quality of the bearing, the conductive medium is treated conductive silicone with a Shore hardness of (45±3)HA, a tensile strength greater than 5.5 MPa, a resistivity less than 100Ω·cm, and a thickness of (2±0.2)mm. It is made into a U-shaped ring by a mold forming process. During measurement, it is tightened with a tightening belt (PVC electrical tape) to achieve full coverage of the conductive silicone on the outer diameter surface and the end surface insulation layer. The appearance of the U-shaped ring is not only suitable for the outer ring insulating bearing,
After improvement, it can also be used to test the insulation resistance of the inner ring insulating bearing, and the production cost is low, which can meet the needs of daily testing.
Wolong Nanyang Explosion Protection, Flameproof three-phase asynchronous motor, high voltage motor