1. Reasons for high current in self-priming pump motor
1. Excessive voltage
One of the main reasons for high current in self-priming pump motor is excessive voltage. When the voltage exceeds the rated voltage of the motor, the motor will absorb too much current, causing the motor to overheat, damage the motor insulation, and affect the life of the motor.
2. Internal fault of the motor
One of the reasons for high current in self-priming pump motor is internal fault of the motor. For example, if the winding of the motor is short-circuited or grounded, the motor current will be too large, which will affect the normal operation of the motor. At this time, the motor needs to be replaced in time.
3. Excessive load
Another reason for high current in self-priming pump motor is excessive load. When the load of the self-priming pump is too large, the motor needs to output more power, so the current will also increase accordingly. At this time, the load of the self-priming pump needs to be checked. If the load is too large, the load needs to be reduced in time.
4. Rotor eccentricity
One of the reasons for high current in self-priming pump motor is rotor eccentricity. When the rotor of the self-priming pump motor is eccentric, the gap between the rotor and the stator of the motor will become larger, thereby reducing the power output of the motor and the current will also increase accordingly. At this time, the motor needs to be replaced in time.
5. Motor overload
One of the reasons for the high current of the self-priming pump motor is motor overload. When the motor load is too large, the motor needs to output more power, which causes the motor to be overloaded, and the current will increase accordingly. At this time, it is necessary to reduce the load or replace the motor in time.

2. Solution to abnormal current of self-priming pump motor
1. Check voltage
When the current of the self-priming pump motor is abnormal, you need to check the voltage first. If the voltage is too high, you need to adjust the voltage; if the voltage is normal, you need to check other faults.
2. Check the inside of the motor
When the current of the self-priming pump motor is abnormal, you need to check whether there is a fault inside the motor. For example, whether there are problems such as winding short circuit or grounding. If so, you need to replace the motor in time.
3. Check the load
When the current of the self-priming pump motor is abnormal, you need to check whether the load of the self-priming pump is too large. If the load is too large, you need to reduce the load in time.
4. Check the rotor eccentricity
When the current of the self-priming pump motor is abnormal, you need to check whether the rotor is eccentric. If the rotor is eccentric, you need to replace the motor in time.
5. Check motor overload
When the motor current of the self-priming pump is abnormal, it is necessary to check whether the motor is overloaded. If the motor is overloaded, it is necessary to reduce the load or replace the motor in time.
High motor current of the self-priming pump is a common problem, which will affect the service life and performance of the self-priming pump and bring a lot of unnecessary trouble to the user. This article analyzes the causes of abnormal motor current of the self-priming pump from the aspects of overvoltage, internal motor failure, excessive load, rotor eccentricity and motor overload, and provides corresponding solutions. I hope this article can provide valuable information for everyone.
Wolong Nanyang Explosion Protection, three-phase asynchronous motor, high voltage explosion proof motor