Seven things to note after the motor is shut down for a long time

2024-10-09

View: 125

After a long shutdown, the humidity, dust and dirt in the environment will have a certain impact on the insulation performance of the motor. Therefore, before resuming operation, it is crucial to measure the insulation resistance value of the motor to ensure that the motor can be started safely. In addition, the condition of the bearings, cooling system and slip rings also needs to be carefully checked, such as the condition of the lubricating oil, the air circulation and the wear of the carbon brushes to ensure that the performance of the motor remains in the best condition.

Here are seven simple inspection steps before starting the motor:

1. Measurement of stator winding insulation resistance

Use an insulation resistance tester to measure the insulation resistance of the stator winding. The usual test voltage is 1000V DC, the test time is 1 minute, and the resistance value is recorded. Before performing the insulation resistance test, take the following precautions:

Make sure that the auxiliary connection of the current transformer (CT) is not open.

Check that all power lines are disconnected.

Make sure that the motor frame and the stator winding not being tested are grounded.

Measure the temperature of the winding and make sure that all resistance temperature sensors are grounded.

2. Measurement of rotor winding insulation resistance

Measure the insulation resistance of the rotor winding using an insulation resistance tester with a test voltage of 1000V DC. Note the following:

Check whether the power supply is disconnected from the power line.

Check whether the cable connection of the slip ring device is disconnected.

Check whether the machine base and stator winding are grounded, and ensure that the shaft is also grounded.

Confirm the connection of the carbon brushes and the normal operation of the measuring device.

Measure the temperature of the stator winding as a reference for the rotor winding temperature.

3. Minimum insulation resistance requirement

Generally, the winding should be kept dry and its insulation resistance value should be much higher than the minimum standard value. Due to different types of motors and different environmental conditions, the insulation resistance value will vary. The following are reference values:

For wound rotor induction equipment: the rotor insulation resistance R (1-10 minutes, 40°C) should be greater than 5 MΩ.

For new stator windings: the insulation resistance R (1-10 minutes, 40°C) should be greater than 1000 MΩ; under high temperature and high humidity conditions, R values exceeding 100 MΩ are also acceptable.

For used stator windings: R (1-10 minutes, 40°C) should be greater than 100 MΩ.

4. Polarization Index Test

The polarization index (PI) is an indicator of the insulation condition of the motor by measuring the insulation resistance after 15 seconds and 1 minute (or 1 minute and 10 minutes). This test is usually performed when the winding temperature is below 50°C to ensure that it is independent of temperature. For class F stator windings, the polarization index should be higher than 2. If the polarization index is lower than this value, it means that the winding may be damp or seriously contaminated.

5. Bearing Inspection

The condition of the bearing directly affects the running quality of the motor:

For sliding bearings, make sure that the oil sump and oil supply system are filled with recommended lubricating oil and filled to the appropriate oil level.

For rolling bearings, manually rotate the rotor to ensure that the bearing runs smoothly and without abnormal noise.

6. Cooling System Inspection

Check the connections of the cooling system regularly to ensure that there are no leaks in the system. Check the condition of the coolant and confirm whether the air circulation is unobstructed to avoid insufficient cooling.

7. Slip ring device inspection

Check the wear of the carbon brushes and replace the worn carbon brushes in time. Make sure the slip ring surface is smooth and intact, otherwise it needs to be repaired. There should be a uniform layer of brown patina on the slip ring, which indicates that it is working properly.

Through these seven steps of inspection, you can ensure that the motor can resume normal operation and achieve optimal performance after a long period of downtime. Regularly performing these inspections can not only improve the reliability of the motor, but also extend its service life.

As a leader in the industry, Nanyang Explosion-proof Motor has always been committed to providing high-quality motor products and professional technical services to ensure that customers' equipment can operate stably for a long time.

WOLONG Nanyang Protection Group,Flameproof three-phase asynchronous motor,high voltage motors