How Thermal Corrosion Affects High-Voltage Motors

How Thermal Corrosion Affects High-Voltage Motors

Electrical reliability is a very important performance requirement for motor products, which is mainly achieved by controlling the temperature rise level of the motor. Therefore, the temperature rise of the motor winding is a key indicator for considering the quality of motor products. This is true for low-voltage motors, and high-voltage motors are no exception. In order to ensure that the motor does not heat up, in addition to leaving enough margin during design, the processing technology during the motor manufacturing process and the specific operating conditions when it is put into use must be thoroughly and carefully investigated or simulated.

Poor welding during the production and processing of windings will cause the local temperature of the windings to rise and the winding resistance to increase; the anti-corona layer of the windings is damaged, which will cause corona discharge when the motor is running; excessive vibration of the motor will damage the winding insulation; conductive foreign matter enters the windings, and the environmental conditions are not good during actual use, which may cause damage to the motor windings. All these factors that may directly cause fatal damage to the conductive windings will threaten the normal operation of the motor. When the winding temperature exceeds the allowable insulation value, the bonding ability and mechanical strength of the insulation are reduced, causing the insulation to flow, age, delaminate, loosen, and peel, which accelerates the thermal corrosion of the insulation and shortens the service life of the coil.

image.png

In the motor repair factory, we can find that the dust accumulation on the surface of many motor windings is very serious, and many of them are charged dust. These are problems that many users tend to ignore. In a general sense, the temperature rise of the motor refers to the temperature of each component in the electronic and electrical equipment that is higher than the environment. After the conductor is energized, the current thermal effect is generated. As time goes by, the temperature of the conductor surface continues to rise until it stabilizes. The criterion for stability is that the temperature difference before and after all test points does not exceed 2K within a 1-hour test interval. At this time, the difference between the temperature measured at any test point and the average ambient temperature of the last 1/4 cycle of the test is called temperature rise, in K. In order to verify the service life, stability and other characteristics of electronic products, the temperature rise of its important components (such as the winding of motor products) is usually tested. The equipment under test is placed at a specific temperature higher than its rated operating temperature. After stabilization, the temperature rise of its components above the ambient temperature is recorded to verify whether the design of this product is reasonable.

In electrical products, the rated temperature rise of the motor refers to the maximum allowable temperature rise of the motor winding under the specified ambient temperature, which depends on the insulation grade of the winding. The temperature rise depends on the heating and heat dissipation of the motor during operation. The normal heat dissipation of the motor is often judged based on the temperature rise. The motor temperature refers to the actual heating temperature of each part of the motor. It has a great influence on the insulation material of the motor. Excessive temperature will cause insulation aging, shorten the life of the motor, and even cause insulation damage. In order to prevent the insulation from aging and damage, the temperature of various parts such as the motor winding is limited. This temperature limit is the allowable temperature of the motor. The motor temperature rise will change under different environmental conditions. When the environmental conditions are poor, such as in plateau environment and sealed environment, the motor temperature rise will increase. Therefore, for motors under different working conditions, necessary program adjustments should be made based on actual conditions.

dust proof motor, Electric Irrigation Pump Motors, Electric Motor Atex Zone

Technical team, Shaanxi Nanfang Motor Technology Co., Ltd.Supplier of Wolong Electric and Nanyang explosion-proof motors, high-voltage motors and VFDs. Questions about this article or your application? Ask our engineers.

Explosion-Proof Motors We Supply