Vertical High-Voltage Flameproof Motor, 160-4500 kW, IM V1
High Voltage Explosion-Proof Motors

Vertical High-Voltage Flameproof Motor, 160-4500 kW, IM V1

Wolong vertical high-voltage flameproof motor (IM V1) for pumps and mixers: 160 - 4500 kW, 3 - 13.8 kV, 500 - 3000 r/min, Ex db / Ex tb, up to IP66, IECEx, ATEX, CSA and UL.
Download product catalogs →
  • Genuine Wolong NanyangOriginal factory nameplate, test report and documents
  • Certified for hazardous areasATEX, IECEx, CSA, EAC, CNEX and CCC certificates held by Wolong Nanyang
  • Model check in 24 hoursEngineers match power, voltage, Ex marking and mounting
  • Worldwide deliverySeaworthy export packing, CIF or with your forwarder

Product Description

Wolong's vertical flameproof motor is a high-voltage induction motor for IM V1 mounting in hazardous areas. Its bearing system carries high axial thrust, which makes it the natural drive for vertical pumps, and it is compact for its rating.

Typical loads are vertical pumps, conveyors, mixers, crushers and winches in oil and gas, petrochemical, chemical, water and mining plants.

Key Specifications

Rated power160 - 4500 kW
Rated voltage3000 - 13,800 V
Speed range500 - 3000 r/min
FrequencyFixed 50 / 60 Hz, or variable-frequency duty
Explosion protectionEx db (gas), Ex tb (dust)
CoolingIC411, IC416, IC511, IC516
Protectionup to IP66
MountingIM V1 (no additional radial load)
BearingsRolling or sleeve
RotorDie-cast aluminium or copper bar
EfficiencyGrade 1 of GB 30254 or IE4 and above
Vibration / noise1.2 mm/s or lower; Lp 85 dB(A) or lower
StandardsGB, IEC, NEMA, BS, API, EN
CertificationIECEx, ATEX, CCC, MA, CSA, UL
Ambient-20 to +40 °C standard, -55 to +60 °C to order; up to 1000 m standard, 1000 - 5000 m to order

Design Features

  • Compact for its rating
  • Bearing arrangement designed for high axial thrust from the pump
  • Long insulation life
  • Larger grease space extends relubrication intervals by 1.5 times
  • Whole-life service support from Wolong

What to Tell Us for a Vertical Motor

  • Pump thrust (down and up) and whether the motor or the pump carries it
  • Flange size and shaft end (solid or hollow shaft)
  • Non-reverse ratchet required or not
  • Rated power, voltage, speed, Ex marking and hazardous zone

Applications

Vertical pumps (including API 610 vertical pumps), conveyors, mixers, crushers and winches in hazardous areas.

Explosion Protection Explained

Dust protection by enclosure ("t") keeps combustible dust out of the motor (IP6X) and limits the surface temperature below the ignition temperature of the dust layer. Zone 21 needs EPL Db (Ex tb), Zone 22 EPL Dc (Ex tc); group IIIC covers conductive dust.

Common Questions

What power range does the this motor cover?

The this motor covers 160 - 4500 kW.

Which voltages are available for the this motor?

Rated voltage: 3000 - 13,800 V. Other voltages can be checked on request.

Which explosion protection does the this motor have?

The marking is Ex db (gas), Ex tb (dust). Tell us the zone, gas group and temperature class of your site and we confirm the right version.

How is the this motor cooled?

Cooling method: IC411, IC416, IC511, IC516.

What is the degree of protection?

Standard protection is up to IP66.

Documents Supplied with the Motor

For each order we can provide the technical data sheet, outline drawing, routine test report and, for explosion-proof motors, a copy of the Ex certificate that matches the nameplate marking. Tell us in the inquiry which documents your project or your inspector requires, so they are prepared before shipment.

Related Products

How to Order

For a fast, accurate quotation please send: rated power (kW), voltage and frequency, number of poles or speed, Ex marking or hazardous zone, mounting type, quantity and destination port. For a replacement, a photo of the old motor nameplate is the quickest way to match it.

Frequently Asked Questions

Do your explosion-proof motors have ATEX and IECEx certificates?

Yes. Wolong Nanyang explosion-proof motors, both low-voltage and high-voltage, are available with ATEX and IECEx certificates for Europe and international projects, and GOST for the Russian market. Tell us which certificate you need when you ask for a quote.

Can this motor replace my existing motor?

Yes. For new projects we quote and select the model to your requirements. For a replacement, please send a nameplate photo or outline drawing of the old motor, and we will match the shaft height, mounting and installation dimensions.

Can you supply replacements for Schorch, Brook Crompton or Morley motors?

Yes. Schorch, Brook Crompton and Morley belong to the Wolong Electric Group, and we can supply Wolong motors built to replace them, matched to your mounting dimensions.

Can you ship to my country, and what is the lead time?

Yes. We ship worldwide on CIF terms, or you can use your own forwarder. The usual production time is about 3 months, depending on the model and quantity.

What information do you need for a quotation?

Rated power (kW), voltage and frequency, number of poles or speed, Ex marking or hazardous zone, mounting type (e.g. B3, B35, V1), quantity and destination port. A nameplate photo of the old motor helps if it is a replacement.

Get a Quote for Vertical High-Voltage Flameproof Motor, 160-4500 kW, IM V1

Send us your requirements. An engineer will reply with a model check and price within 24 hours.

We only use your details to reply to this inquiry.

TEL

+86 13609288011

Motor Price Inquiry

WhatsApp QR code

WhatsApp